The opportunity of choice between the various models, sizes and finishes
is still further
extended by a range of accessories.
 |
BACK PLATES
For a practical solution and professional appeal use our stainless
steel back plates. They are reinforced with MDF and are available
in 60, 70, 80, 90, 100, 110 or 120cm widths and 650 or 750mm
heights. The new fitting flanges with depths of 20mm and 36mm
make them suitable for almost all cooker hoods including our
Glacier models.
|
 |
| CHIMNEY KITS
To accommodate different kitchen installations we offer stainless
steel chimney extension kits for Igloo, Key and Tamaya. Short
kits for Key and Tamaya are also available.
PLATE RACK AND SHELF
Our unique plate rack and shelf, provides an ingenious and
attractive space saving solution. It has been designed to complement
the Spot cooker hoods but can be effectively used as a standalone
unit.
|
 |
 |
PLINTH HEATERS
A 2 kW built-in electric fan heater designed for installation
in standard kitchen furniture plinths with 1 kW and 2 kW heat
settings and neon indicator.
|
Because it is normally hidden, a ducting system is often
not considered an important part of the construction or refurbishment
of a building. However, the importance of the correct ducting
is slowly becoming recognized by the building industry.
It is not always the fault of the cooker hood manufacturer
when dreams of fresh kitchens and low noise are not achieved.It
can often be that the size or configuration of ducting has
been incorrectly selected by the installer or system designer.
As it cannot be seen,air movement is often made more complicated
than it actually is. Air moves just as water moves and it is
sometimes useful to visualise a problem by substituting it
with water.
In ventilation installations the aim is normally to move the
air from its source to the outside of the house as efficiently
and quietly as possible. It is, therefore, common sense that
to do this effectively, the shorter the distance that the air
has to travel, the quicker the aim is achieved. It is also
common sense that if an obstacle is put in the way,such as
a bend, the process will become more difficult as the air will
lose its momentum and require more powerful assistance in order
to achieve the aim.
Cooker hoods vary in power just as cars do and the results
are reflected in much the same way. A high performance/specification
car should be quieter, last longer and generally provide the
driver with more comfortable and satisfactory results. However,
to ensure this,the car needs a straight smooth road on which
to travel efectively.The road for the air to travel when using
a cooker hood is the ducting. Again, it is common sense that
amore powerful cooker hood would need a more efficient duct
a Rolls Royce owner would not consider driving their car off-road!
It is worth remembering that many cooker hood manufacturers ’ guarantees
will be invalidated if the correct size of ducting is not used
to match the power of the cooker hood.
A few key installation guidelines can be applied to help ensure
that the ducting selection is correct and installed in a way
that optimises the cooker hoods performance.
| • |
Choose the shortest and most direct route to outside. |
| • |
Ensure that bends are kept to a minimum. |
| • |
Check the extraction capability and connection size of
the cooker hood and choose an appropriate size of ducting.
Refer to the cooker hood manufacturer for performance ratings
and specifications. |
| • |
A round duct provides optimum air flow performance and
should be used if installation space allows. |
| • |
Rectangular or flat channel ducting is an excellent alternative
when space is restricted. Its low profile enables the ducting
to be easily concealed in the ceiling void or along the
top of wall units. |
| • |
A rigid duct is more efficient than a flexible duct and
should be used whenever possible. |
| • |
If flexible hose is used,the hose should remain taut
and as straight as possible. |
| • |
Provision should be made for make up air.In most dwellings
this is catered for by natural leakage. However, some high
performance products may require the installation of an
air supply set. |
Important
If installing a cooker hood in a room containing an open-flued
fuel-burning appliance (ie non-balanced flue), there must be
sufficient replacement air to prevent fumes being drawn back
down the flue when the cooker hood is set to maximum extract.
Exhaust air must not be discharged into a flue used for exhausting
fumes from appliances supplied with energy other than electricity.When
deciding the method for exhaust air discharge and intake flow
rates, the requirements of all relevant authorities must be strictly
adhered to.
If the duct passes through an unheated roof void the duct should
be insulated to reduce the formation of condensation. A vertical
duct should also be installed with a weatherproof roof cowl of
sufficient free area for the air volume. 220mm x 90mm rectangular
rigid ducting or 150mm round aluminium ducting must be used when
installing models which are supplied with external motors.
Horizontal ducts should fall away from the cooker hood.
| • |
Made from flame retardant self extinguishing materials
to conform to us fire standard UL94 V2 and also to DIN
4102 B1 |
| • |
Maximum working temperature of 60 °c |
| • |
Bends and adapters meet most installation requirements |
| • |
Lightweight and easy to install |
| |
Size |
Application |
Dimensions |
Cross Section |

Up to 250m³/hr |
4"
(100mm) |
Particularly suitable for applications
requiring lower extraction rates, such as the ventilation
of lower powered cooker hood with 100mm exhaust spigots,
domestic bathrooms and internal WCs.
Provides efficient ducting for short, simple runs. |
Flat channel outer dimensions
are 110 x 54mm and fit into system parts sockets.
Minimum space required:
115 x 60mm |

Free Area:
5,300mm² |

Up to
500m³/hr |
5"
(125mm) |
Ideal for the ducting of medium
powered kitchen cooker hoods and fans with 125mm round
exhaust spigots.
Highly efficient even for long runs, and with appliances
of a high extraction rate. |
Flat channel outer dimensions
are 204 x 60mm and fit into system parts sockets.
Minimum space required:
210 x 65mm |

Free Area:
11,200mm² |

500m³/h and above |
6"
(150mm) |
Ideal for the ducting of very
high powered cooker hoods,especially those with 150mm exhaust
spigots.
This highly efficient rectangular duct has a comparable
air flow per formance of a 150mm round duct, but its lower
profile provides the fitter or system designer with greater
installation flexibility. |
Flat channel outer dimensions
are 220 x 90mm and fit into system parts sockets.
Minimum space required:
227 x 97mm |

Free Area:
17,968mm² |
|
One of these ducting kits will be ideal for most situations.
They are designed for cooker hoods with 100mm dia. ducting outlets
and for bathroom extraction systems. The flexible hose kits may
also be used for tumble dryers.
Each par t may be ordered separately, so to extend any of these
kits, simply order the appropriate kit plus extra part.
Please ring for advice regarding special applications such as
ducting into or through chimneys.
Cooker hoods up to 250 m³/hr
 |
| 4RD2R |
Rectangular/Round Connector |
|
4D18D |
Round to Round 90 °Bend |
| 4RD3R |
Round/Rectangular Elbow with Socket |
4D300F |
Round Flexi Hose 3M Long |
| 4R30R |
Rectangular Rigid Duct 300mm Long |
4D600F |
Round Flexi Hose 6M Long |
| 4RD03R |
Round/Rectangular Elbow with Spigot |
4D150A |
Round aluminum duct 1.5M Long |
| 4R04R |
Rectangular Connector |
4D300A |
Round aluminum duct 3M Long |
| 4R5R |
Rectangular Horizontal Elbow |
4R300F |
Rectangular Flexi Hose 3M Long |
| 4R6R |
Rectangular Vertical Elbow |
4D100R |
Round Pipe 1M Long |
| 4R7R |
Rectangular Duct Retaining Clip |
4R100R |
Rectangular Rigid Duct 1M Long |
| 4D8R-BR |
Cowled Wall Vent Round Socket -Brown |
4DCLIP |
Hose Clip |
| 4D8R-WH |
Cowled Wall Vent Round Socket -White |
4DALUCLIP |
Aluminum Duct Clip |
| 4R9R-BR |
Cowled Wall Vent Rectangular Socket -Brown |
TAPE33 |
33M PVC Adhesive Tape |
| 4R9R-WH |
Cowled Wall Vent Rectangular Socket -White |
4D30-55R |
Round Adjustable Pipe |
| 4D11R |
Threaded Hose Adapter 100mm I.D.
|
4D14R |
Fixed Louvred Grille Round Socket |
| 4D12R |
Threaded Hose Adapter 100mm O.D. |
4D17R |
4” to 5” Adapter |
| 4R13R |
Adapter (4R100R-5R7R) outlet |
4D5D |
Universal Offset Ducting Spigot |
| 4D15D |
Round Pipe Connector |
UB41 |
Universal Roof Vent |
| 4R16R |
Round Pipe Connector +Damper |
|
|
 |
One of these ducting kits will be ideal for most situations.
They are designed for cooker hoods with 125mm dia. ducting outlets
and for bathroom extraction systems.
Each part may be ordered separately, so to extend any of these
kits, simply order the appropriate kit plus extra part.
Cooker hoods up to 500 m³/hr
 |
| 5DR1R |
Rectangular/Round Connector |
|
5D15R |
Connector for Round Rigid Duct |
| 5DR2R |
Round/Rectangular Vertical Elbow |
5D16R |
Round Pipe Connector and Damper |
| 5R3R |
Rectangular Vertical Elbow |
5D17R |
Wall Outlet with Gravity Flap |
| 5R100R |
Rectangular Rigid Duct 1M Long |
5D100R |
Round Pipe 1M Long |
| 5R30R |
Rect Rigid Duct 300mm Long |
5D300F |
Round Flexible Hose 3M Long |
| 5D30-55R |
Round Adjustable Telescopic Pipe |
5D600F |
Round Flexi Hose 6M Long |
| 5R4R |
Rectangular Horizontal Elbow |
5D150A |
Round aluminum duct 1.5M Long |
| 5R40R |
Rectangular Rigid Duct 400mm Long |
5D300A |
Round aluminum duct 3M Long |
| 5R5R |
Connector Rectangular Rigid Duct |
5DCLIP |
Hose Clip |
| 5R6R |
Connector Rectangular Flexi Duct |
5DALUCLIP |
Aluminum Duct Clip |
| 5R6D |
125mm to 150mm Adapter |
TAPE33 |
33M PVC Adhesive Tape |
| 5R7R |
Wall Vent Rectangular Outlet |
5D18D |
Round to Round 90° Bend |
| 5D8R |
Wall Vent Round Outlet |
5R300F |
Rectangular Flexi Hose 3M Long |
| 5D11R |
Threaded Hose Adapter |
5R19R |
Flat Channel clip |
| 5D14R |
Wall Plate |
UB41 |
Universal Roof Vent |
Maximum airflow performance can be achieved with 150mm dia.
ducting. Particularly suitable for larger fans and more powerful
cooker hoods.
Separate parts can be ordered using appropriate code. Please
ring for further advice.
Cooker hoods
500m³/h and above
 |
| 6D1R |
Louvred Wall Vent |
|
6DR1R |
Rectangular/Round Connector |
| 6D2R |
Cowled Wall Outlet |
6R6R |
Connector for Rectangular Rigid Ducting |
| 6D300F |
3 metre 6” (150mm) Flexi Hose |
6R8R |
Horizontal Bend |
| 6D600F |
6 metres 6” (150mm) Flexi Hose |
6R9R |
Vertical Bend |
| 6D150A |
Round Aluminum Duct 1.5M Long |
6R100R |
Rectangular Rigid Duct 100cm Long |
| 6D300A |
Round Aluminum Duct 3M Long |
6R19R |
Flat Channel Clip (one needed either side) |
| 6DCLIP |
Hose Clip 6” (150mm) |
6D100R |
Round Rigid Pipe 100cm Long |
| 6D4R |
Round/Rectangular Elbow (150mm round/
6R100R 150mm Rectangular) |
6R300F |
Flexible Rectangular Hose 3M Long |
| 6D11R |
Threaded Hose Connector (150mm) |
6R7R |
Double Airbrick |
| 6D16R |
Round Pipe Connector and Damper |
6R3R |
Double Airbrick Adapter |
| 6D21R |
Round Pipe Connector |
6DALUCLIP |
Aluminum Duct Clip |
| 6D17R |
Wall Outlet with Gravity Flap |
UB41 |
Universal Roof Vent |
| 6D18D |
Round to Round 90° bend |
|
|
|